Noise Pollution from Agricultural Machinery and Its Impact on Users in the Wasit District

Authors

  • Asst.lect Haitham Abdul-Kazim Razij al-Jawhari University of Wasit College of Education for the Humanities
  • Asst.lect Mohammed Qasim Hamid Al-Badiri University of Wasit College of Education for the Humanities
  • Asst.lect Karim Alawi Khalid Al-Kaabi University of Wasit College of Education for the Humanities

DOI:

https://doi.org/10.31185/eduj.Vol65.Iss2.5690

Keywords:

agricultural machinery, noise pollution, decibels, environmental pollution

Abstract

Noise is considered one of the serious environmental problems affecting the health of agricultural machinery users, . This study aimed to measure the pollution emitted by agricultural machinery using a sound level meter, with the decibel (dB) as the unit of measurement for noise. The agricultural machinery whose noise emissions were measured included the combine harvester, agricultural tractor, excavator, grader, and water pumps.

The results of noise measurement for the combine harvester without a cabin ranged between (100–110) dB, while inside the driver's cabin it ranged between (80–105) dB. Both levels are significantly higher than the permissible limit of (85 dB) for an eight-hour working period.

For agricultural tractors, the measurement results showed that noise levels during plowing ranged between (80–105) dB inside the driver's cabin (and could reach up to 110 dB outside it), which is also well above the permissible limit.

As for the excavator, the study results showed that noise levels ranged between (95–120) dB inside the operator's cabin and could reach up to (130) dB near crushers or hydraulic breakers, far exceeding the permissible level.

The noise measurement results for the grader showed that noise levels ranged between (85–105) dB inside the cabin and could reach up to (115) dB outside the cabin, exceeding the permissible limit.

For diesel-powered water pumps, the measurement results showed that noise levels ranged between (90–115) dB at a distance of one meter. As for surface electric pumps, the measurement results showed noise levels ranging between (55–75) dB, which falls within the permissible limit. Submersible electric pumps, on the other hand, have much lower noise levels than surface pumps; they are known as silent pumps, with noise ranging between (40–50) dB, which is also within the permissible limit.

Views: 0Downloads: 0

Downloads

Download data is not yet available.

References

Hurni, H., Giger, M., Liniger, H., Studer, R. M., Messerli, P., Portner, B., Schwilch, G., Wolfgramm, B., & Breu, T. (2015). Soils, agriculture and food security: the interplay between ecosystem functioning and human well-being. Current Opinion in Environmental Sustainability, 15, 25–34. DOI: https://doi.org/10.1016/j.cosust.2015.07.009

الباز, د. (1998). حماية السكنية العامة. دار النهضة العربية.

القط, ا. ع., & المليان, ك. م. (2022). التلوث الضوضائي ودرجة وعي المواطنين به-مدينة الزاوية دراسة حالة. Al-Qurtas, 17.

تاج الدين ،الراجحي, ت. ا. ع. ،. ا. ب. ه. (1998). التلوث والبيئة الزراعية. في جامعة الملك سعود ،الرياض.

جمعة, م. ا. (1996). علم البيئة. في علم البيئة. جامعة عمر المختار.

سعيد, أ. م. (1994). استقراء لقواعد المسؤولية المدنية في منازعات التلوث البيئي. في استقراء لقواعد المسؤولية المدنية في منازعات التلوث البيئي. دار النهضة العربية.

عبد الحسين, ه. ج. (2013). التلوث الضوضائي واثره في البيئة الصحية للمستهلك ، بحوث السوق وحماية المستهلك. في ه. جعفر (محرر), بحوث السوق وحماية المستهلك. جامعة بغداد.

موسى, ع. (2006). البيئه والتلوث. في البيئه والتلوث. مطبعه ابن حيان.

Downloads

Published

2026-11-25

Issue

Section

Articles

How to Cite

Asst.lect Haitham Abdul-Kazim Razij al-Jawhari, Asst.lect Mohammed Qasim Hamid Al-Badiri, & Asst.lect Karim Alawi Khalid Al-Kaabi. (2026). Noise Pollution from Agricultural Machinery and Its Impact on Users in the Wasit District. Journal of College of Education, 65(2), 467-480. https://doi.org/10.31185/eduj.Vol65.Iss2.5690